Kimball
Kimball LaB6 cathodes for SEM Scanning Electron Microscope and TEM Transmission Electron Microscope Lab 6

Kimball LaB6 cathodes for SEM and TEM

 

Kimball LaB6 cathodes for SEM and TEM
Kimball LaB6 cathodes for SEM and TEM

Introduction

The Kimball LaB6 filaments are the industry standard, high quality LaB6 cathodes. The standard LaB6 cathode comprises a 90° tip angle and a 15µm flat made from a <100> oriented single crystal. This provides a long lifetime, high brightness source coupled with excellent stability.  The special version with sharper 60° tip angle and smaller 6µm flat is available for TEMs.
Kimball Physics uses the purest, high quality LaB6 crystals for the Kimball ES-423E LaB6 cathodes. The standard Kimball LaB6 tip provides a 10x higher brightness as the standard tungsten source, resulting in better resolution with clear images and less noise. The lifetime of an LaB6 cathode is much longer than a tungsten source providing a stable source over a longer period.

 

The Kimball LaB6 cathodes improve results when used for:

  • SEM for low voltage and long term EDS mapping applications
  • TEM imaging and analysis
  • Electron probe micro analyzers (EPMA or Microprobe)
  • E-beam lithography

The Kimball LaB6 cathodes are available with three types of LaB6 tips

The Kimball LaB6 cathodes are available with three types of LaB6 tips:

1 – Standard tip with 90° cone and 15 µm micro-flat for standard SEM and standard TEM applications
2 – Long life, high stability tip with 90° cone and 20 µm micro-flat for Microprobes and analytical SEM applications
3 – High brightness, sharp tip with 60° cone and 6 µm micro-flat for high resolution TEM applications

LaB6 sources require a higher vacuum than standard tungsten sources which generally requires an additional ion-getter pump at the electron source. The required vacuum is in the 10-7 mbar range.

 

Design and features of the Kimball ES-423E LaB6 cathodes

Kimball-ES-423E-LaB6-EM-cathodes-for-SEM-and-TEM-tipThe Kimball Physics ES-423E (extended life) LaB6 cathode is a high performance, resistively heated, thermionic electron source. It is based on a well proven carbon rod heater structure with improved stability, improved reliability and less exposure of the LaB6 crystal to reduce contamination of the Wehnelt aperture. There is heating current through the LaB6 crystal; there are no high-temperature current carrying joints. The LaB6 crystal is held in place by a carbon ferrule. The design results in a small physical size which fits most Wehnelt cylinder with ease. Benefits of this unique construction are:

  • Suitable for SEM, TEM, Microprobes and E-Beam lithography systems
  • Resistively, indirectly heated high purity LaB6 crystal, resulting in lower heating current
  • High thermal stability to eliminate drift problems
  • Carbon ferrule with less exposure of LaB6 crystal to reduce Wehnelt contamination
  • low vapour pressure with reduced evaporation loss
  • High brightness; about 10x higher than tungsten filaments (even 20x for the sharper tips)
  • Stable sources; due to its sturdy construction, the standard Kimball LaB6 cathodes comprise a stability of better than 3%/hour at 1550°C
  • Long life; at 10-7mbar vacuum and 1550°C operating temperature, >500 hours lifetime can be expected for the standard Kimball ES-423E LaB6 cathode
  • Low work function of 2.66ev (compared to 4.7ev for tungsten)

 

Specifications of the different Kimball ES-423E LaB6 cathodes

Please consult the following table for the correct type of Kimball LaB6 source or cathode for your SEM, TEM or Microprobe. The Kimball Physics LAB6 cathodes are available for Thermo, FEI, Hitachi, JEOL, Amray, CamScan, ISI, ABT, Topcon, Philips, Tescan, Zeiss, LEO, Leica, Cambridge Instruments and Leica electron microscopes.

Type Standard tip Long life, high stability tip High brightness sharp tip
Tip shape 90°tip angle with 15µm flat 90°tip angle with 20µm flat 60°tip angle with 6µm flat
Brightness
Value
10x times than tungsten tip
1 x 106 A/cm2.Str
2 x less than standard tip
0.5 x 106 A/cm2.Str
2x times than standard tip
2 x 106 A/cm2.Str
Saturation Mono spot at around 1550°C Mono spot at around 1550°C Mono spot at around 1550°C
Crossover Small; 7-10µm Small; 7-10µm Small; 7-10µm
Angular distribution Sharp; 1.6 x 10-2 rad Sharp; 1.6 x 10-2 rad Sharp; 1.6 x 10-2 rad
Lifetime Long > 500 hrs Longer than standard tip Shorter than standard tip
Ease of operation Moderate Easy, due to larger spot Difficult, due smaller spot
Stability High, better than 3%/hr High, better than 3%/hr Lower, due to smaller spot
Vacuum 10-7 mbar or better 10-7 mbar or better 10-7 mbar or better
Work function 2.66 ev 2.66 ev 2.66 ev
Application SEM & TEM Analytical SEM / Microprobe TEM

 

Kimball ES-423E LaB6 cathode selection table

Electron Microscope Type or Filament base

Product number

Ceramic Disc mm

Pin Diameter  mm

Pin Pitch mm

AEI

14-AE3501

12.0

1.0

6.45

AmRay /AMR SEM (except 1200 series)

14-AM3502

26.0

1.0

5.0

Cambridge Instruments SEM (except S4-10)

14-AE3501 / 14-AE3521

12.0

1.0

6.45

CamScan SEM with AEI conversion

14-AE3501

12.0

1.0

6.45

FEI SEM and TEM

14-FP3503 / 14-FP3563

26.0

1.0

5.0

Hitachi S-Type

14-HI3504 / 14-HI3564

9.8

1.2

2.7

JEOL K-Type metal ring – SEM – standard tip

14-JL3508

28.0

1.2

8.0

JEOL K-Type metal ring – TEM – sharp tip

14-JL3568

28.0

1.2

8.0

Leica SEM

14-AE3501

12.0

1.0

6.45

LEO 400 and 1400 Series SEM

14-AE3501

12.0

1.0

6.45

LEO1450 SEM (except AEI conversions)

14-ZS3510

19.8

1.0

5.0

LEO TEM

14-ZS3560

19.8

1.0

5.0

Philips SEM and TEM (except XL-30)

14-FP3503 / 14-FP3563

26.0

1.0

5.0

Philips XL-30 SEM

14-AE3501

12.0

1.0

6.45

Tescan SEM

14-TN3509

19.8

1.0

5.0

Thermo Sem and TEM

14-FP3503 / 14-FP3563

26.0

1.0

5.0

Zeiss DSM SEM and TEM

14-ZS3510 / 14-ZS3560

19.8

1.0

5.0

Zeiss EVO SEM

14AE3501 / 14-AE3521

12.0

1.0

6.45

 

 

Electron Source Performance Table

The electron source performance table is provided to give additional information into the performance and requirements for different type of electron emitters. Tungsten cathodes are still used in many SEMs. Improved results can be obtained with LaB6 cathodes. The highest resolution, highest brightness and best low kV performance can be achieved with either Schottky or cold Field Emission Sources.

 

Emitter Type

Thermionic

Thermionic

Schottky TFE

Cold FE

Tip image comparison Thermionic Wolframe Cathode Thermionic LaB6 Cathode chottky TFE ZrO/W (100) Cathode Cold Fe W (310) cathode
Cathode Material W LaB6 ZrO/W (100) W (310)
Operating Temp (K) 2700 1800 1800 300
Cathode Radius (nm) 60,000 10,000 <1000 <100
Effective Source Radius (µm) 25 10 0.015 0.0025
Emission Current Density (A/cm2) 3 30 5300 17,000
Total Emission Current (µA) 200 80 200 5
Brightness (A/cm2.sr.kV) 1x104 1x105 1x107 2x107
Maximum Probe Current (nA) 1000 1000 10 0.2
Energy Spread @ Cathode (ev) 0.59 0.4 0.31 0.26
Energy Spread @ Source Exit (eV) 1.5 – 2.5 1.3 – 2.5 0.35 – 0.7 0.3 – 0.7
Beam Noise (%) 1 1 1 5 – 10
Emission Current Drift (%/h) 0.1 0.2 <0.5 5
Operating Vacuum (hPa/mbar) <10-5 <10-6 <10-8 <10-10
Typical Cathode Life (h) 100 >1000 >5000 >2000
Cathode Regeneration (h) None None None 6-12
Sensitivity to External Influences Minimal Low Low High
Stability Standard High Very high Low
X-ray analysis EDS / WDS EDS / WDS EDS / WDS EDS